ZRC

ZRC SPRAY ZINC AEROSAL

95% zinc in the dry film using only Type III “ultra pure” ASTM-D-520 zinc

Technical Data

TYPE
Single pack, premixed, ready to apply, liquid organic zinc compound
THEORETICAL COVERAGE
400 ft²/gal @ 1.5 mil dry film thickness
METALLIC ZINC CONTENT
95% by weight in dry film
FLASH POINT
111°F (44°C) (SETA method, ASTM D3278)
VOC CONTENT
3.3 lbs/gal (385 gms/ltr) (ASTM D3960)
WEIGHT PER GALLON
24 lbs. (ASTM D1475)
SOLIDS CONTENT
86% (by weight)/52% (by volume)
VISCOSITY
1900 cps. Brookfield spindle #5 @ 100 RPM, @ 25°C
MAXIMUM SERVICE TEMP - Intermittent
750°F (399)°C
MAXIMUM SERVICE TEMP - Constant
350°F (177)°C
ELECTRICAL CONDUCTIVITY
73 million ohms per square @ 3 mils dry (resistivity)
IMPACT RESISTANCE
Greater than 30 inch-lbs. (extrusion) per ASTM-D2794
ABRASION RESISTANCE
11.5 liters per dry mil (tested @ 3 dry mils) per ASTM-D98-51
POT LIFE
At least 24 hrs
PACKAGING
3.5 gallon pails, gallon, quart, half-pint and aerosol cans
DRY TIME
Set to touch. When ambient air dried, 20-30 min. @ 1.5 mil (38μ) thickness
RECOAT TIME
(Second Coat) 12 hrs.
TOPCOATING
After 24-48 hrs., topcoat with acrylic, epoxy, urethane or vinyl type products. DO NOT USE alkyd, alkyd-modified acrylic, or lacquer type products. Consult our Guide to Topcoating for detailed instructions.


• 95% zinc in the dry film using only Type III “ultra pure” ASTM-D-520 zinc

• Meets and exceeds Fed. Spec. DOD-P-21035A (Galvanizing Repair Spec);MIL-P-26915A (USAF Zinc Dust Primer); ASTM Des. A-780 (Standard) Practice for Repair of Damaged Hot-Dip Galvanized Coatings; SSPC-Paint20 (Specification for Zinc-Rich Primer)

• Passes 3,000 hours salt spray testing without failure (ASTM Des. B117)

• Passes Preece Test (ASTM Des. A239) for hot-dip galvanizing

• Passes 9-year subtropical testing

• Low VOC approved in all 50 states

• ISO 9001 registration assures the highest quality consistently